| General properties |
| Density |
ISO 1183 |
g/cm³ |
1.14 |
| Water absorption (23°C/50% RH) |
- |
% |
3.5 |
| Flammability |
DIN 4102 |
- |
HB |
| Specific heat capacity |
- |
kJ/kg·°C |
1.7 |
| Mechanical properties |
| Tensile strength |
DIN 53455 |
N/mm |
80 |
| Elongation at break |
DIN 53455 |
% |
30 |
| Elastic modulus |
DIN 53457 (23°C) |
N/mm² |
3000 |
| Flexural strength |
DIN 53452 |
N/mm² |
130 |
| Impact strength (Charpy) |
DIN 53453 (23°C) |
Charpy |
3 |
| Shore hardness |
- |
Shore D |
82 |
| Coefficient of friction |
- |
- |
0.5 |
| Electrical properties |
| Relative permittivity (100Hz) |
DIN 53485 (100Hz) |
100 Hz |
3.7 |
| Dielectric loss factor (100Hz) |
DIN 53483 |
tan (×10⁻³) |
0.027 |
| Volume resistivity |
DIN 53482 |
Ω·cm (10¹⁶) |
>10 |
| Surface resistivity |
DIN 53482 |
Ω (10¹³) |
>10 |
| Comparative tracking index |
DIN 53480 |
KC |
>600 |
| Dielectric strength |
DIN 53481 |
kV/mm |
20 |
| Thermal properties |
| Crystalline melting point |
- |
°C |
220 |
| Thermal conductivity |
DIN 52162 |
W/m·K |
0.23 |
| Linear thermal expansion coefficient |
DIN 53762 |
mm/m·°C |
0.07 |
| Service temperature (long-term, unloaded) |
- |
°C |
-40 to 80 |
| Max. service temperature (short-term) |
- |
°C |
160 |
| Heat deflection temperature |
DIN 53461 |
°C |
95 |
| Temperature range |
| Minimum temperature |
- |
°C |
-40 |
| Maximum temperature |
- |
°C |
+80 |